CXS lighting is a private enterprise led by industrial lighting appliances, integrating R & D, manufacturing, trade and service functions. The main products are fixed professional lighting, mobile professional lighting, fixed explosion-proof lighting, mobile explosion-proof lighting, explosion-proof electrical appliances and other professional products. There are dozens of series, hundreds of varieties and specifications of products. At present, it is one of the most professional enterprises in China, and its products are complete. Now he is the vice president of Yueqing overseas entrepreneur association, the member of Yueqing private enterprise association, and the demonstration unit of China credit enterprise certification system.
According to the company's development strategy, we should expand the national market, enhance the competitiveness of enterprises and expand the social influence of the company. In March 8, 2018, the company officially established the Lishui office in Zhejiang. The company appointed Comrade Luo Mingjin as the head of the office of the Lishui.
In the ten years of CXS lighting business, CXS has entered the headquarters economic Park in Yueqing to meet the wave of the new era and create better and better services. The place of entry is just like the creation of the Gulf of fortune, to create the most beautiful Yueqing, the best industrial lighting brand.

Tel: 0577-62128886
Fax: 0577-62128889
Mailbox: cxs@imaysolutions.com
Website: imaysolutions.com
Address: Tiancheng Industrial Zone, Yueqing, Zhejiang
Lighting solutions
Current location: Home Page > Solution Mobile lighting solutions
How to install and maintain mine flameproof roadway lights?

Operation and use

1 open the four M6 nuts of the top cover, and connect the power cord to the side hole waterproof rubber plug and the side hole hollow steel piece, and penetrate through the threaded hole of the side hole.

2 the power cord is connected to the inner cavity zero line, the fire line and the ground wiring terminal, and the screw nut and the ground screw are loaded. When installing the zero line and the fire line nut, the M5 six angle socket wrench is needed.

3 use the spanner to thread the side hole thread and load the power cord to compress the steel sheet. The side hole plug must be tightly pressed to prevent the water from penetrating into the cavity, resulting in short circuit or damage to the power supply.

4 sets of good coping, tighten the cover and fix the nut; note that the cover ring must be installed.

5 if a lamp is installed by cascading mode, a steel plunger must be used at the end of the power supply line at the end of the cascade.

Product installation

1 this product is suitable for 127V power supply network.

2 when you open the lamp cover and install the cable, you must cut off the power supply and open the top cover. The sealing ring of the device can be used to cross the cable of 10mm or 14mm. If the cable with other specifications is used, please match the sealing ring of the corresponding inner diameter. When the wire is connected with the terminal, it is necessary to keep the electrical clearance equal to 5mm. Connect the power cord to the wiring terminal of the wiring board and connect the ground wire to the ground screw. It is necessary to tighten the flat pad, pad and nut to prevent loosening. Tighten the pressure plate to prevent the power cord from loosening and shifting. Return the lamp cap to the original position, connect the power cord through the cable tightening joint and the wiring sealing ring, then tighten the cable tightening joint so that the cable sealing ring is tightly sealed.

3 the parts of the transparent parts are connected by screws when they are out of factory.

4 when the upper and lower shells are locked, the positioning screws must be tightened. Otherwise, when positioning the transparent cover parts, the positioning screws must be loosened.

5 attention should be paid to rubber washers between transparent cover and protective mesh. If there is aging phenomenon, it should be replaced in time.

Failure analysis and troubleshooting

1 the maintenance of roadway lights must be carried out by our plant maintenance personnel or trained by qualified professionals in our well. It is strictly prohibited to remove any parts of roadway lights.

2 no parts of the laneway lamp must be dismantled without authorization. After damage, we should purchase new model parts from our factory. Troubleshooting causes analysis troubleshooting method note lights are not lit, voltage is not supplied, the power cable is disconnected or the lanes inside the lanes are disconnected, LED or the driving circuit board is burned, the power input is checked, the control switch is checked, and the cable fault is eliminated. The roadway lamp casing and explosion proof outlet box are damaged by external force.

Transport storage requirements

Lane lights are not allowed during transportation.

 